Title: Point-of- care blood tests during home visits by out-of- hours primary care clinicians; a mixed methods evaluation of a service improvement
Authors: Garland, Sophie
Hunt, Helen
Keywords: Blood Tests
Issue Date: Jan-2020
Citation: Gail Hayward ,Sharon Dixon, Sophie Garland, Margaret Glogowska,Helen Hunt, Daniel Lasserson. Point-of- care blood tests during home visits by out-of- hours primary care clinicians; a mixed methods evaluation of a service improvement. BMJ Open 2020;10:e033428
Abstract: Objectives We aimed to evaluate test usage and patient and clinician experience following the introduction of point-of- care (POC) blood tests into a primary care out-of- hours service. Design A mixed methods service evaluation comprising quantitative records of the clinical contexts of tests taken and qualitative interviews with clinicians. Research permissions and governance were obtained for patient interviews. Setting Out-of- hours primary care. Participants All patients requiring home visits from the service during the implementation period. Interventions The i-STAT POC blood test platform was introduced to two bases providing home visits for a period of 8 months. Venous blood samples were used and two cartridges were available. The CHEM8 cartridge measures sodium, potassium, chloride, total carbon dioxide (TCO2), anion gap, ionised calcium, glucose, urea, creatinine, haematocrit and haemoglobin. The CG4 cartridge measures lactate, pH, PaO2 and PCO2, TCO2, bicarbonate, base excess and oxygen saturation. Primary and secondary outcome measures The proportion of home visits where tests were taken, the clinical contexts of those tests, the extent to which clinicians felt the tests had influenced their decisions, time taken to perform the test and problems encountered. Clinician and patient experiences of using POC tests. Results i-STAT POC tests were infrequently used, with successful tests taken at just 47 contacts over 8 months of implementation. The patients interviewed felt that testing had been beneficial for their care. Clinician interviews suggested barriers to POC tests, including practical challenges, concerns about time, doubt over whether they would improve clinical decision making and concern about increased medicolegal risk. Suggestions for improving adoption included sharing learning, adopting a whole team approach and developing protocols for usage. Conclusions POC tests were not successfully adopted by an out-of- hours home visiting service in Oxfordshire. While some clinicians felt they could not add value, in other cases they resulted in improved patient experience. Adoption could be promoted by improving technical, team and education factors.
URI: https://oxfordhealth-nhs.archive.knowledgearc.net/handle/123456789/495
ISSN: 2044-6055
Appears in Collections:Primary Care
Nursing Research
Oxford Healthcare Improvement (OHI)

Files in This Item:
File Description SizeFormat 
BMJ Open Garland e033428.full.pdfMain article326.21 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.